mitao
2 天以前 6365012e69b76d2a7804f5a462745f09a5fa0105
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
package com.ruoyi.system.model;
 
import com.baomidou.mybatisplus.annotation.IdType;
import com.baomidou.mybatisplus.annotation.TableField;
import com.baomidou.mybatisplus.annotation.TableId;
import com.baomidou.mybatisplus.annotation.TableLogic;
import com.baomidou.mybatisplus.annotation.TableName;
import io.swagger.annotations.ApiModel;
import io.swagger.annotations.ApiModelProperty;
import lombok.Data;
import lombok.EqualsAndHashCode;
 
import java.io.Serializable;
import java.time.LocalDateTime;
 
/**
 * <p>
 * 巡检明细表
 * </p>
 *
 * @author WuGuanFengYue
 * @since 2025-09-15
 */
@Data
@EqualsAndHashCode(callSuper = false)
@TableName("asset_house_inspection_detail")
@ApiModel(value="AssetHouseInspectionDetail对象", description="巡检明细表")
public class AssetHouseInspectionDetail implements Serializable {
 
    private static final long serialVersionUID = 1L;
 
    @ApiModelProperty(value = "主键")
    @TableId(value = "id", type = IdType.AUTO)
    private Integer id;
 
    @ApiModelProperty(value = "巡检记录ID,关联asset_house_inspection_record表")
    @TableField("inspection_record_id")
    private Integer inspectionRecordId;
 
    @ApiModelProperty(value = "巡检项ID,关联asset_inspection_item表")
    @TableField("inspection_item_id")
    private Integer inspectionItemId;
 
    @ApiModelProperty(value = "巡检项名称(冗余字段)")
    @TableField("item_name")
    private String itemName;
 
    @ApiModelProperty(value = "巡检子项ID,关联asset_inspection_item表")
    @TableField("sub_item_id")
    private Integer subItemId;
 
    @ApiModelProperty(value = "巡检子项名称(冗余字段)")
    @TableField("sub_item_name")
    private String subItemName;
    @ApiModelProperty(value = "备注")
    @TableField("remark")
    private String remark;
 
    @ApiModelProperty(value = "巡检结果:1-正常、0-异常")
    @TableField("inspection_result")
    private Boolean inspectionResult;
 
    @ApiModelProperty(value = "创建人")
    @TableField("create_by")
    private String createBy;
 
    @ApiModelProperty(value = "更新时间")
    @TableField("update_time")
    private LocalDateTime updateTime;
 
    @ApiModelProperty(value = "更新人")
    @TableField("update_by")
    private String updateBy;
 
    @ApiModelProperty(value = "是否删除 0-否,1-是")
    @TableField("disabled")
    @TableLogic
    private Boolean disabled;
 
 
}